Estimating the right solar PV size for a UK business starts with electricity use, not the available roof area. This guide shows how to turn annual consumption, panel output, roof constraints, orientation and shading into a practical first estimate for an office, shop, workshop, warehouse or farm building.

Overview

The question “how many solar panels do I need?” has no single answer. A small office with modest daytime demand may need a very different system from a workshop with machinery, refrigeration or electric vehicle charging. The most useful starting point is to estimate the solar capacity in kilowatt-peak (kWp), then check whether the roof can accommodate it and whether the generation profile matches the business’s operating hours.

For commercial solar panels in the UK, the main variables are:

  • Annual electricity consumption in kilowatt-hours (kWh).
  • Expected annual generation per installed kWp.
  • The rated output of the chosen panels, usually stated in watts (W).
  • Roof area, roof condition, orientation, pitch and shading.
  • How much electricity the business uses while the system is generating.
  • Any export, connection, planning, insurance or structural constraints.

A calculation based only on roof size can produce an oversized system. A calculation based only on annual consumption can produce a system that does not fit, generates too much surplus at certain times or needs a more detailed grid-connection assessment. Use the method below as a screening tool before requesting commercial solar quotes.

How to estimate

Step 1: Find annual electricity use

Collect at least 12 months of electricity bills or half-hourly meter data. Record total consumption in kWh, then note the monthly pattern. A business with the same annual use all year may be easier to size than one with seasonal refrigeration, heating, production or holiday closures.

If you do not have a full year of data, add the available monthly figures and clearly mark the estimate as provisional. Avoid using a single bill as the annual figure unless the business has an unusually stable load.

Step 2: Choose an indicative generation assumption

Use a conservative, clearly labelled estimate for annual generation per kWp. The appropriate assumption depends on location, roof direction, pitch, shading, panel technology, inverter performance and system losses. A solar installer can model these factors more accurately using the site address and roof plan.

The core formula is:

Required system size (kWp) = annual electricity consumption (kWh) ÷ estimated annual generation per kWp

For example, if a business uses 30,000 kWh a year and your working assumption is 900 kWh generated per kWp, the initial system size is approximately 33.3 kWp. This is an annual-energy estimate, not a guarantee that the system will meet demand in every month.

Step 3: Convert kWp into panel numbers

Panel output varies by product. Convert the system size into watts, then divide by the panel rating:

Number of panels = required system size in kWp × 1,000 ÷ panel rating in watts

For the 33.3 kWp example, a 400 W panel assumption gives approximately 84 panels. In practice, round up to a whole panel and then check the result against roof layout, inverter sizing and available electrical capacity. The final design may use a slightly different system size to avoid awkward gaps or to match the manufacturer’s equipment range.

Step 4: Check self-consumption

Annual generation is only part of the business case. Solar electricity used directly on site generally has a different value from electricity exported, so compare the generation profile with operating hours. Offices may have strong weekday demand, while a farm building or warehouse may have substantial daytime loads from pumps, refrigeration, conveyors or lighting. A shop may need to account for opening hours and seasonal trading.

Where daytime use is limited, consider whether battery storage, load shifting or scheduled EV charging would improve the use of generated electricity. Storage should be assessed alongside battery capacity, power output, warranty terms, controls and the business’s tariff structure rather than added automatically.

Inputs and assumptions

Use this worksheet for an initial commercial solar sizing review:

  1. Annual consumption: ______ kWh.
  2. Estimated generation per kWp: ______ kWh/kWp/year.
  3. Indicative system size: annual consumption ÷ generation assumption = ______ kWp.
  4. Panel rating: ______ W.
  5. Indicative panel count: system size × 1,000 ÷ panel rating = ______ panels.
  6. Usable roof area per panel: ______ square metres, including practical spacing and access allowances.
  7. Total roof area required: panel count × usable area per panel = ______ square metres.

Panel dimensions and mounting layouts differ, so do not treat a simple panel-area multiplication as a structural or construction plan. Leave room for maintenance access, roof edges, rooflights, fire-safety requirements, vents, plant and shading obstacles. A survey should also check roof age, waterproofing, loading capacity, asbestos risk where relevant, and access for installation.

Orientation matters. A south-facing roof may produce a different annual and hourly profile from an east-west roof, while nearby trees, parapets, plant or taller buildings can reduce output. Splitting panels across roof faces can also affect inverter design and the timing of generation. For technical planning, review our commercial roof screening checklist and panel and inverter compatibility checklist.

Grid connection should be considered before committing to an exact design. Larger systems or changes to export arrangements may require a network assessment or application. Read the G98, G99 and DNO checklist as part of the early planning process.

Worked examples

The following figures are illustrative, not production guarantees. Replace the generation assumption with a site-specific estimate before making an investment decision.

Business typeIllustrative annual useWorking generation assumptionIndicative systemApproximate panels at 400 W
Small office12,000 kWh900 kWh/kWp/year13.3 kWp34
Retail shop20,000 kWh900 kWh/kWp/year22.2 kWp56
Workshop45,000 kWh900 kWh/kWp/year50 kWp125
Warehouse100,000 kWh900 kWh/kWp/year111.1 kWp278

These examples show why consumption alone is not enough. A warehouse may have sufficient roof area but need a detailed structural survey and grid review. A small office may have a suitable roof but limited weekday demand during school or holiday closures. A workshop may benefit from aligning high-load equipment with solar generation rather than maximising panel count.

For each project, compare at least three design options: a roof-limited system, a system sized around daytime demand, and a larger system with export and storage assumptions. Record the expected self-consumption, export, annual generation, inverter capacity and any planned future loads such as heat pumps or EV chargers. If storage is under consideration, assess it separately using the business’s load profile; our battery planning and health guidance can help structure that review.

When to recalculate

Revisit the estimate whenever the inputs change, rather than treating the original calculation as permanent. Recalculate at least when:

  • Electricity consumption rises or falls materially.
  • Opening hours, shifts or seasonal operations change.
  • New machinery, refrigeration, heating, EV chargers or battery storage is installed.
  • The roof is repaired, extended, resurfaced or fitted with new plant.
  • Shading changes because of trees, buildings or equipment.
  • Panel wattages, inverter options, installation costs or tariff assumptions change.
  • A proposed system is expanded or altered after the original grid review.

Keep a simple annual record of billed consumption, solar generation, exported electricity and major operational changes. Compare actual performance with the installer’s model, allowing for weather and downtime before concluding that a system is underperforming. The solar performance log provides a practical framework.

Before requesting final solar quotes UK businesses should prepare 12 months of bills, half-hourly data if available, roof drawings or photographs, details of operating hours, planned loads and any lease or landlord constraints. Ask each installer to show the assumptions behind panel count, annual generation, self-consumption, export, inverter selection and connection requirements. That makes competing proposals easier to compare and gives the business a sizing model that can be updated when its energy use changes.